FM Transmitter Measurement Report
Created: 2025-07-21 11-33-20
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.60 MHz 5/5, 73 dBuV P3 SR
Pilot RDS Phase Difference
6.5 kHz 3.5 kHz 76 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 30 kHz 16654 0,0781
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-2,8 dBr -1,31 dBr 1,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"P3 SR " E203 9 (Varied) 0 1 1 9 10:33, 21.07.2025
RT
"Chic - Good Times n d Margret Atladottir och Branne Pavlovic "
AF EON
97.9, 99.0, 99.4, 100.5 MHz E201, E402, E224, E424
FM Scope Max at: 30 kHz MIN: 9 kHz % above 76 kHz: 0,0781 Acquired: 2025/07/21 11.32.16 Total samples: 16654 Equivalent time: 0:13:52 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: 1,3 dBr MIN: -2,8 dBr AVE: -1,31 dBr % above 12,2 dBr: 0,0 Last value: -2,2 dBr (2025/07/21 11.32.16) 11.18 11.20 11.22 11.24 11.26 11.28 11.30 11.32 -3 -2 -1 0 1 2 Pm [dBr]